Renovation scope for the building permit
Draft for review. Owner's summary of the planned work. The general contractor and the electrical and plumbing subcontractors confirm every item and count before submission.
Bathroom 61 × 87 in. Walk-in closet 61 × 49 in behind it, door from the bedroom.
12 new light fixtures and 4 replacing existing fixtures, plus the outlets, switches and fan below. Still to decide: 2nd floor Living room, 3rd floor Bedroom.
| Floor | # | Room | Item | New / replace | Notes |
|---|---|---|---|---|---|
| 1st floor | 2 | Laundry room | Recessed light | New | Recessed light (2 total in the laundry): one over the washer/dryer, one over the sink. Damp-rated, bright and cool-white for seeing stains. On one switch by the door. |
| 1st floor | 3 | Laundry room | Recessed light | New | Recessed light (2 total in the laundry): one over the washer/dryer, one over the sink. Damp-rated, bright and cool-white for seeing stains. On one switch by the door. |
| 1st floor | 4 | Half bathroom | Recessed light | Replace existing | Recessed light replacing the hanging light. Damp-rated. |
| 2nd floor | 1 | Kitchen | Recessed light | Replace existing | Recessed light, replacing one of the 2 pendants (pendants removed). |
| 2nd floor | 2 | Kitchen | Recessed light | Replace existing | Recessed light, replacing one of the 2 pendants (pendants removed). |
| 2nd floor | 3 | Dining area | Recessed light | New | Recessed light (1 of 4), new. The existing chandelier is removed (its box capped or reused). |
| 2nd floor | 4 | Dining area | Recessed light | New | Recessed light (1 of 4), new. The existing chandelier is removed (its box capped or reused). |
| 2nd floor | 5 | Dining area | Recessed light | New | Recessed light (1 of 4), new. The existing chandelier is removed (its box capped or reused). |
| 2nd floor | 6 | Dining area | Recessed light | New | Recessed light (1 of 4), new. The existing chandelier is removed (its box capped or reused). |
| 2nd floor | 7 | Living room | Recessed light (count to be decided) | New | ADD RECESSED LIGHTS: how many still to decide. Placeholder; the GC/electrician to propose a layout. |
| 3rd floor | 1 | Master bathroom | Outlet for toilet bidet seat | New | Coway bidet SEAT on a regular toilet (12 in rough-in). Needs a GFCI outlet beside the toilet, placed per Coway's install guide; T-valve on the toilet water line. |
| 3rd floor | 3 | Master bathroom | Other electrical | New | Lighted mirror (Wrought Studio 28 in round, W115625530). It can be hardwired: put a junction box behind the mirror, on a switch at the door, so no cord shows. No outlet needed if hardwired. |
| 3rd floor | 4 | Master bathroom | Switch | New | Switches by the entry door (door is opposite the vanity), on the latch side: ceiling light, exhaust fan, lighted mirror. Drag this to the exact spot. |
| 3rd floor | 10 | Master bathroom | GFCI outlet (wet area) | Confirm existing | CONFIRM on site: GFCI outlet at the vanity for a hair dryer and toothbrush, beside the vanity, about 42 in up (above the 35.7 in counter). Add one if it isn't there. |
| 3rd floor | 11 | Primary bedroom | Recessed light | New | Recessed light (1 of 4), new. |
| 3rd floor | 12 | Primary bedroom | Recessed light | New | Recessed light (1 of 4), new. |
| 3rd floor | 13 | Primary bedroom | Recessed light | New | Recessed light (1 of 4), new. |
| 3rd floor | 14 | Primary bedroom | Recessed light | New | Recessed light (1 of 4), new. |
| 3rd floor | 15 | Bedroom | Recessed light (count to be decided) | New | ADD RECESSED LIGHTS in the bedroom across from the bathroom: 2 or 4, still to decide. Placeholder. |
| 3rd floor | 16 | Hall | Recessed light | Replace existing | Recessed light replacing the hanging light in the 3rd floor hall. |
| 3rd floor | 17 | Master bathroom | LED strip (shelf or niche) | New | LED strip under the full-width shower shelf. Wet-rated strip; the power supply (driver) goes outside the shower where it can be reached. On a switch. |
| 3rd floor | 18 | Master bathroom | Exhaust fan | New | Exhaust fan, vented OUTSIDE (no window in this bathroom). Humidity or timer switch by the door. |
| 3rd floor | 19 | Master bathroom | Recessed light | New | Ceiling light over the walkway (new). Damp-rated recessed, on the switch by the door. |
Numbers match the # column above. Orange = electrical, blue = plumbing, red = wall work or blocking.
| Toilet | New toilet (regular, comfort height) with a Coway bidet seat. Location changes with the new layout, so the toilet drain (closet flange) and water supply move. 12 in rough-in from the finished wall. T-valve on the supply for the bidet seat. |
| Shower | New shower 61 x 42 in. New shower valve: Delta rough-in valve with pressure balance (anti-scald) for the Delta Modern trim; shower head plus hand shower on a slide bar. New square center drain (VIGO Elan 4 in) with the shower floor sloped to it in penny round mosaic, new waterproofing, low curb at the entry unless the floor can be recessed. Sliding glass door. |
| Vanity | New 30 in wall-mounted (floating) vanity: drain and hot/cold supply come out of the wall between 18 and 35.7 in above the finished floor. Wood blocking in the wall. |
| Other floors (same locations) | Half bath: replace the toilet and the small vanity in place. Laundry: new 20 in laundry sink with cabinet (drain and hot/cold supply); washer and dryer replaced. |